Super Duplex 2507 CapASTM A815 · ASME B16.9 · Manufacturer, trader & exporter, India
UNS S32750 · W.Nr 1.4410
A Super Duplex 2507 cap is a fitting that closes the end of a pipe, made from Super Duplex 2507 to ASTM A815 WPS32750 (buttweld) · ASTM A182 F53 (forged). Buttweld caps are dished ends welded to the pipe; forged caps are threaded or socket-weld. Used at dead ends and future connection points.
- ASTM A815
- ASME B16.9
- EN 10204 3.1 / 3.2
- Export packing
Reviewed by the Kanak Steel & Engineering Co. technical team · Updated October 2026
What is a Super Duplex 2507 Cap?
- What it is
- A fitting that closes the end of a pipe
- Material
- ASTM A815 WPS32750 (buttweld) · ASTM A182 F53 (forged)
- Dimensions
- ASME B16.9 · B16.11
- Grade
- Super Duplex 2507 · UNS S32750
- Best at
- Seawater and high-chloride service where strength also matters
Super Duplex 2507 Cap Specification
| Product | Super Duplex 2507 Cap |
|---|---|
| Material standard | ASTM A815 WPS32750 (buttweld) · ASTM A182 F53 (forged) |
| Dimensional standard | ASME B16.9 · B16.11 |
| Sizes | Buttweld ½" – 48" · forged ⅛" – 4" |
| Wall / class | Schedule to match pipe · Class 3000 / 6000 (forged) |
| Ends | Bevelled to ASME B16.25 |
| Testing | PMI (as specified in the PO) · dimensional · NDT and IGC on request |
| Documents | EN 10204 3.1 or 3.2 on request / as specified in the PO |
When to Choose a Cap
Buttweld caps are dished ends welded to the pipe; forged caps are threaded or socket-weld. Used at dead ends and future connection points.
- Buttweld dished caps
- Threaded and socket-weld caps
- Wall to match the pipe
More on choosing: Cap guide.
Super Duplex 2507 Cap: Why 2507 for caps
Buttweld caps are dished ends welded to the pipe; forged caps are threaded or socket-weld. Used at dead ends and future connection points. In Super Duplex 2507, the choice usually comes down to the medium and temperature — the rows here are the points buyers check for this exact combination.
| Why this grade | Duplex fittings match duplex pipe in chloride service and strength. Super Duplex 2507 is picked for seawater and high-chloride service where strength also matters. |
|---|---|
| Typical service | Offshore & subsea — Seawater injection, firewater and subsea piping. |
| Welding to carbon steel | ER2209 or ER309L(Mo) is used when joining it to carbon steel, under a qualified WPS |
| Matching filler | ER2594 (AWS A5.9) |
| Sour service | Listed in NACE MR0175 / ISO 15156-3 within its limits — state it on the order |
Super Duplex 2507 Cap Chemical Composition
Under technical review for TDS.
| Element | Current requirement |
|---|---|
| Chromium | As specified |
| Nickel | As specified |
| Molybdenum | As specified |
| Nitrogen | As specified |
| Copper | As specified |
| Carbon | As specified |
| Manganese | As specified |
| Silicon | As specified |
Numerical specification requirements are published only after the applicable current standard edition has been verified. Governing specification to be verified: ASTM A240 for UNS S32750.
Super Duplex 2507 Cap Mechanical Properties
Under technical review for TDS.
| Property | Current requirement |
|---|---|
| Tensile strength | As specified |
| Yield strength 0.2% | As specified |
| Elongation | As specified |
| Hardness | As specified |
Numerical specification requirements are published only after the applicable current standard edition has been verified. Governing specification and condition to be verified: ASTM A240 for UNS S32750 — Solution-annealed plate & sheet.
Full chemistry, properties and equivalents are on the Super Duplex 2507 grade page.
Standards on this page
Other Super Duplex 2507 pipe fittings
Super Duplex 2507 Cap dimensions — ASME B16.9
Values in mm, the same for every material; the wall thickness matches the pipe schedule.
| NPS | OD | Cap length E |
|---|---|---|
| ½" | 21.3 | 25 |
| ¾" | 26.7 | 25 |
| 1" | 33.4 | 38 |
| 1½" | 48.3 | 38 |
| 2" | 60.3 | 38 |
| 3" | 88.9 | 51 |
| 4" | 114.3 | 64 |
| 6" | 168.3 | 89 |
| 8" | 219.1 | 102 |
| 10" | 273.1 | 127 |
| 12" | 323.9 | 152 |
| 16" | 406.4 | 178 |
| 20" | 508.0 | 229 |
| 24" | 610.0 | 267 |
Full chart: ASME B16.9 fitting dimensions.
Super Duplex 2507 Cap — questions buyers ask
Can a cap take full line pressure?
Yes — a buttweld cap of matching schedule is rated like the pipe it closes.
Can Super Duplex 2507 caps be welded to carbon steel?
Yes — ER2209 or ER309L(Mo) is used when joining it to carbon steel, under a qualified WPS.
Which standard covers Super Duplex 2507 caps?
The material is ASTM A815 WPS32750 (buttweld) · ASTM A182 F53 (forged); dimensions follow ASME B16.9 · B16.11. Always state both on your purchase order, with the edition if your project specifies one.
What decides the price of a Super Duplex 2507 cap?
The alloy price, the size and schedule or class, quantity, and the testing and documents required. Send your list and we quote the same working day.
Can you supply Super Duplex 2507 caps to NACE MR0175?
Yes. Super Duplex 2507 is listed in NACE MR0175 / ISO 15156-3 within its limits; state NACE compliance on the order and it is confirmed on the certificate.
What documents do you supply?
EN 10204 3.1 or 3.2 certificates available on request / as specified in the PO; dimensional reports as required. PMI can be arranged depending on product and requirements, as specified in the PO.
Sources: the ASTM / ASME specifications named on this page and producer datasheets · Last updated October 2026